Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Horizontal Bone Augmentation in the Posterior Atrophic Mandible and Dental Implant Stability Using the Tenting Screw Technique
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 41 , Issue 4
July/August 2021

Pages e147–e155


Horizontal Bone Augmentation in the Posterior Atrophic Mandible and Dental Implant Stability Using the Tenting Screw Technique


Daniel Farias, DDS/Felipe Caceres, DDS, MSc/Antonio Sanz, DDS/Sergio Olate, DDS, MSc, PhD


PMID: 34328475
DOI: 10.11607/prd.5137

The aim of this study was to analyze horizontal bone augmentation using the tenting screw technique in the posterior mandible. Included subjects had a 3-mm bone width and 9-mm bone height, measured by CBCT. After the surgical approach, two to four screws were inserted, leaving 4 mm of extraosseous space; reconstruction was achieved using allogeneic biomaterial and leukocyte- and platelet-rich fibrin together with an absorbable membrane. After 4 months, a new CBCT scan was obtained to compare the bone gain and implant placement. Early and secondary stability were measured by the implant stability quotient (ISQ); prosthetic load was performed 16 weeks later. Student t test was used to compare bone gains and implant stability, with significance set at P < .05. Fourteen subjects and 27 surgical sites initially exhibited a mean bone width of 2.95 ± 0.75 mm. Four months after augmentation, the bone width was 7.15 ± 1.87 mm, confirming a significant bone gain (4.2 ± 1.26 mm). Twenty-seven implants were placed with a minimum insertion torque of 35 Ncm; the primary stability was 69.3 ± 7.16 ISQ, and the secondary stability was 75.9 ± 3.29 ISQ (P > .05). It may be concluded that the tenting screw technique is predictable in terms of bone gain and that it facilitates implant stability.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help